Changes to Irish Building Regulations

U Value requirement

1. Pitch Roof - Sloping ceilings Insulation at rafter level U value 0.20 W/m²K
2. Cold Roof - Attic space Insulation at ceiling level U value 0.16 W/m²K
3. Flat Roof - U value 0.22 W/m²K
4. Dwarf Wall - Room in the roof Insulation fitted between timber studs U value 0.21 W/m²K
5. External Walls U value 0.27 W/m²K
6. Ground Floor Standard heating system U value 0.25 W/m²K
7. Ground Floor Under floor heating system U value 0.15 W/m²K


The Building Regulations  December 1st 2011         [ CHANGES ]

Part L Conservation of Fuel and Energy

U Value requirement

1. Pitch Roof - Sloping ceilings   Insulation at rafter level   U value 0.16  W/m²K
2. Cold Roof - Attic space   Insulation at ceiling level  U value 0.16  W/m²K
3. Flat Roof - U value 0.20  W/m²K
4. Dwarf  Wall - Room in the roof   Insulation fitted between timber studs  U value 0.27  W/m²K
5. External Walls  U value 0.21  W/m²K
6. Ground Floor   Standard heating system  U value 0.21  W/m²K
7. Ground Floor   Under floor heating system  U value 0.15  W/m²K

 

Your target should always be to achieve the lowest U Value possible.  The lower the U value the slower the heat loss.  The lower the U Value the cheaper the energy costs.

< back to news listings